 Advanced Digital Temperature Controller
E5AN-H/E5EN-H
(96 x 96 mm and 48 x 96 mm)
CSM_E5AN-H_E5EN-H_DS_E_3_2
A New High-performance Controller: High Resolution, High Speed, and High Input Accuracy. Logic Operations and Preventive Maintenance Function. Plus Infrared Port on Front Panel.
* High-resolution display with 5 digits/0.01C display. * High-speed sampling cycle of 60 ms. * High Accuracy Thermocouple/Pt input: 0.1% of PV Analog input: 0.1% FS * Universal inputs on all models (thermocouple, PT, or analog input) to handle various sensors with one Controller. Models also available with Remote SP. * A PV/SV-status display function can be set to automatically alternate between displaying the status of the Temperature Controller (auto/manual, RUN/STOP, and alarms) and the PV or SV. * Flexible contact outputs with logic operations (AND, OR, and delays) set from the Support Software (CX-Thermo Ver. 4.0) * Preventive maintenance for relays in the Temperature Controller using a Control Output ON/OFF Counter. * Model available with position-proportional control
96 x 96 mm E5AN-H
48 x 96 mm E5EN-H
Refer to Safety Precautions for E5@N/E5@N-H. Refer to Operation for E5@N/E5@N-H for operating procedures.
Main I/O Functions
Remote SP Input * One Event Inputs * None * Two * Four Universal Sensor Inputs * Universal thermocouple/ Pt/analog (current/voltage) inputs. Indication Accuracy * Thermocouple/Pt input: 0.1% of PV * Analog input: 0.1% FS Sampling Period * 60 ms PF Key (Programmable key function)
E5AN-H
E5EN-H
3-level Display Simultaneously displays set items, such as the PV, SV, and MV. 5-digit Display with high resolution of 0.01C * Auto/manual switching * Temperature Controller status display * Simple program function * Logic operations * Control output ON/OFF count alarm * PV change rate alarm * Models available with RS-485, RS-422, or RS-232C communications
Infrared port
Auxiliary Outputs * Two * Three Computer Support Software CX-Thermo
USB
Control Output 2 (built-in) Output Unit * SSR outputs * Relay output * Voltage output (for driving SSR) * Current output * Linear voltage output Control Output 1 (built-in) Output Unit * SSR outputs * Relay output * Voltage output (for driving SSR) * Current output * Linear voltage output
1
E5AN-H/E5EN-H
Lineup
1 control output
2 auxiliary outputs
E5AN-H/E5EN-H
Advanced Type
Terminal block
Fully universal input 2 control outputs
2 auxiliary outputs
Note: The Controller can be used for heating/cooling control even if only 1 control output is used.
Model Number Structure
Model Number Legend
Controllers Option Units
E5AN/E5EN-@@@@@@@M@-@-500
1 2 3 4 5 6 7 8 9 10
1. Type H: Advanced 2. Control Mode Blank: Standard or heating/cooling control P: Position-proportional control 3. Control Output 1 A: Control Output Unit R: Relay output S: SSR output 4. Control Output 2 A: Control Output Unit R: Relay output S: SSR output 5. Auxiliary Outputs 2: Two outputs 3: Three outputs 6. Option 1 Blank: None H: Heater burnout/SSR failure/Heater overcurrent detection (CT1) HH: Heater burnout/SSR failure/Heater overcurrent detection (CT2) 7. Option 2 B: Two event inputs BF: Event input + Transfer output 8. Option 3 M: Option Unit can be mounted. 9. Power Supply Voltage Blank: 100 to 240 VAC D: 24 VAC/VDC 10.Case Color Blank: Black W: Silver 11.Terminal Cover -500: With Terminal Cover
E53-@
1
1. Function EN01: RS-232C communications EN02: RS-422 communications EN03: RS-485 communications AKB: Event input
11
Output Units
E53-@@
12
1. Control Output R: Relay output Q: Voltage output (for driving SSR) Q3: Voltage output (for driving SSR) + 24 VDC (NPN) Q4: Voltage output (for driving SSR) + 24 VDC (PNP) C3: Current output + 4 to 20 mA DC C3D: Current output + 0 to 20 mA DC V34: Linear voltage output + 0 to 10 VDC V35: Linear voltage output + 0 to 5 VDC 2. Version Blank: Available for E5AN-E5EN-H and E5AK/E5EK. N: Available only for E5AN-H/E5EN-H.
This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions and other information required for operation before attempting to use the product. E5CN-H/E5AN-H/E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157) E5CN-H/E5AN-H/E5EN-H Digital Controllers Communications Manual Advanced Type (Cat. No. H159)
2
E5AN-H/E5EN-H
Ordering Information
E5AN-H
Size Case color Power supply voltage Control Auxiliary method output Control output 1/2 Control Output Unit x 2 SSR outputs x 2 2 Control Output Unit x 2 Basic 100 to 240 VAC 3 SSR outputs x 2 Relay outputs x 2 Valve Black Control Output Unit x 2 1/4 DIN 96 x 96 x 78 (W x H x D) Basic 24 VAC/ VDC 3 SSR outputs x 2 Relay outputs x 2 Valve 2 Relay outputs x 2 Control Output Unit x 2 Basic 2 Control Output Unit x 2 Control Output Unit x 2 1 2 1 2 2 2 2 2 2 SSR outputs x 2 Control Output Unit x 2 2 2 2 SSR outputs x 2 2 Control Output Unit x 2 2 2 1 1 2 2 2 Relay outputs x 2 2 2 2 SSR outputs x 2 Control Output Unit x 2 2 2 2 2 2 Heater burnout 1 1 Optional functions Event inputs 2 2 Transfer output RSP Model
4 to 20-mA E5AN-HAA2HBM-500 input 4 to 20-mA E5AN-HSS2HBM-500 input 4 to 20-mA 4 to 20-mA E5AN-HAA2HHBFM-500 output input 4 to 20-mA 4 to 20-mA E5AN-HSS2HHBFM-500 output input 4 to 20-mA 4 to 20-mA E5AN-HAA3BFM-500 output input 4 to 20-mA 4 to 20-mA E5AN-HSS3BFM-500 output input 4 to 20-mA E5AN-HPRR2BM-500 input 4 to 20-mA 4 to 20-mA E5AN-HPRR2BFM-500 output input 4 to 20-mA E5AN-HAA2HBMD-500 input 4 to 20-mA E5AN-HSS2HBMD-500 input 4 to 20-mA 4 to 20-mA E5AN-HAA2HHBFMD-500 output input 4 to 20-mA 4 to 20-mA E5AN-HSS2HHBFMD-500 output input 4 to 20-mA 4 to 20-mA E5AN-HAA3BFMD-500 output input 4 to 20-mA 4 to 20-mA E5AN-HSS3BFMD-500 output input 4 to 20-mA E5AN-HPRR2BMD-500 input 4 to 20-mA 4 to 20-mA E5AN-HPRR2BFMD-500 output input 4 to 20-mA E5AN-HAA2HBM-W-500 input 4 to 20-mA 4 to 20-mA E5AN-HAA2HHBFM-W-500 output input 4 to 20-mA E5AN-HAA2HBMD-W-500 input
Silver
100 to 240 VAC 24 VAC/ VDC
3
E5AN-H/E5EN-H
E5EN-H
Size Case color Power supply voltage Control method Auxiliary output Control output 1/2 Control Output Unit x 2 SSR outputs x 2 2 Control Output Unit x 2 Basic SSR outputs x 2 100 to 240 VAC Control Output Unit x 2 3 SSR outputs x 2 Relay outputs x 2 Valve Black Control Output Unit x 2 1/8 DIN 48 x 96 x 78 (W x H x D) Basic SSR outputs x 2 24 VAC/VDC Control Output Unit x 2 3 SSR outputs x 2 Relay outputs x 2 Valve 2 Relay outputs x 2 Control Output Unit x 2 100 to 240 VAC Silver 24 VAC/VDC Basic 2 Control Output Unit x 2 Control Output Unit x 2 2 1 2 2 1 2 2 2 2 2 2 2 SSR outputs x 2 2 Control Output Unit x 2 2 2 1 1 2 2 2 Relay outputs x 2 2 2 2 2 2 2 2 2 Optional Functions Heater burn- Event Transfer RSP out inputs output 1 1 2 2 Model
4 to 20-mA E5EN-HAA2HBM-500 input 4 to 20-mA E5EN-HSS2HBM-500 input 4 to 20-mA 4 to 20-mA E5EN-HAA2HHBFM-500 output input 4 to 20-mA 4 to 20-mA E5EN-HSS2HHBFM-500 output input 4 to 20-mA 4 to 20-mA E5EN-HAA3BFM-500 output input 4 to 20-mA 4 to 20-mA E5EN-HSS3BFM-500 output input 4 to 20-mA E5EN-HPRR2BM-500 input 4 to 20-mA 4 to 20-mA E5EN-HPRR2BFM-500 output input 4 to 20-mA E5EN-HAA2HBMD-500 input 4 to 20-mA E5EN-HSS2HBMD-500 input 4 to 20-mA 4 to 20-mA E5EN-HAA2HHBFMD-500 output input 4 to 20-mA 4 to 20-mA E5EN-HSS2HHBFMD-500 output input 4 to 20-mA 4 to 20-mA E5EN-HAA3BFMD-500 output input 4 to 20-mA 4 to 20-mA E5EN-HSS3BFMD-500 output input 4 to 20-mA E5EN-HPRR2BMD-500 input 4 to 20-mA 4 to 20-mA E5EN-HPRR2BFMD-500 output input 4 to 20-mA E5EN-HAA2HBM-W-500 input 4 to 20-mA 4 to 20-mA E5EN-HAA2HHBFM-W-500 output input 4 to 20-mA E5EN-HAA2HBMD-W-500 input
Accessories (Order Separately)
Output unit Relay output Voltage output (for driving SSR) Model E53-RN E53-QN E53-Q3 E53-Q4 E53-C3N E53-C3DN E53-V34N E53-V35N Specifications SPST-NO, 250 VAC, 5 A (resistive load), electrical life: 100,000 operations 12 VDC (PNP), max. load current: 40-mA, with short-circuit protection 24 VDC (NPN), max. load current: 20-mA, with short-circuit protection 24 VDC (PNP), max. load current: 20-mA, with short-circuit protection 4 to 20-mA DC, load: 600 max., resolution: approx. 10,000 0 to 20-mA DC, load: 600 max., resolution: approx. 10,000 0 to 10 VDC, load: 1 k min., resolution: approx. 10,000 0 to 5 VDC, load: 1 k min., resolution: approx. 10,000
Terminal Cover
Connectable models E5AN-H Model
E53-COV16 E5EN-H Note: The Terminal Cover comes with the E5CN-@@@-500 models.
Waterproof Packing
Connectable models E5AN-H Model Y92S-P4
E5EN-H Y92S-P5 Note: The Waterproof Packing is included with the Controller.
Current output
Current Transformers (CTs)
Hole diameter 5.8 dia. 12.0 dia. Model E54-CT1 E54-CT3
Linear voltage output
CX-Thermo Support Software
Model EST2-2C-MV4
USB-infrared Conversion Cable
Model E58-CIFIR
USB-Serial Conversion Cable
Model E58-CIFQ1
4
E5AN-H/E5EN-H
Specifications
Ratings
Power supply voltage Operating voltage range Power consumption No D in model number: 100 to 240 VAC, 50/60 Hz D in model number: 24 VAC, 50/60 Hz; 24 VDC 85% to 110% of rated supply voltage 100 to 240 VAC: 12 VA 24 VAC/VDC: 8.5 VA (24 VAC)/5.5 W (24 VDC) Any of the following can be selected. Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II Platinum resistance thermometer: Pt100 or JPt100 Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V Current input: 150 max., Voltage input: 1 M min. (Use a 1:1 connection when connecting the ES2-HB.) ON/OFF control or 2-PID control (with auto-tuning)
Sensor input
Input impedance Control method Relay output Voltage output (for driving SSR) Control output Current output Linear voltage output Built-in SSR output Relay output for position-proportional control Auxiliary output Number of outputs Output specifications Number of outputs Event input External contact input specifications Number of operations
Output Unit (Install the Output Unit (sold separately).)
75 to 250 VAC, 1 A (resistive load) Relay output: Open and close: SPST-NO, 250 VAC, 1 A (including in-rush current), electrical life: 100,000 operations min. Potentiometer input: Must be between 100 and 2.5 k for maximum open position. 2 or 3 max. Relay output: SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA 2 or 4 (with an E53-AKB) Contact input: ON: 1 k max., OFF: 100 k min. Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max. Current flow: Approx. 7 mA per contact 8 max. * Logic operation: Any of the following four patterns can be selected. The input status may be inverted. (A and B) or (C and D), (A or C) and (B or D), A or B or C or D, A and B and C and D (A, B, C, and D are four inputs.) * Delay: ON delay or OFF delay for the results of the logic operation given above. Setting time: 0 to 9999 s or 0 to 9999 min * Output inversion: Possible One work bit per operation Any of The following can be assigned to up to eight work bits (logic operation results): Event input operations, auxiliary outputs, or control outputs. 1 max. (Depends on model. Models with transfer output (F in model number) Current output: 4 to 20 mA DC, Load: 600 max., Resolution at 4 to 20 mA: Approx. 10,000 1 Current input: 4 to 20 mA (input impedance: 150 10%) Scaling of signal to engineering units (EU) -19,999 to 30,000 (display: 30,000 max.) (0.2% of FS) 1 digit max. 60 ms Set digitally using keys on the front panel or by using the RSP input. 11-segment digital display and individual indicators (7-segments displays also possible) Character height: E5AN-H: PV: 15.8 mm, SV: 9.5 mm, MV: 6.8 mm; E5EN-H: PV: 11.8 mm, SV: 8.1 mm, MV: 5.8 mm Content of 3-level display: PV/SV/MV, PV/SV/Bank No., or soak time remain Number of digits: 5 for PV and SV, 4 for MV Supported (number of banks: 8) Local SP, alarm settings, PID sets (PID constants, MV upper limit, MV lower limit, etc.) Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout detection, 40% AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop, protection functions, control output ON/OFF counter, extraction of square root, MV change rate limit, PV/SV status display, logic operations, automatic cooling coefficient adjustment -10 to 55C (with no condensation or icing), for 3-year warranty: -10 to 50C 25% to 85% -25 to 65C (with no condensation or icing)
Logic operations
Operations
Output Work bit assignment Transfer outputs Number of outputs Output specifications Number of inputs Signal type RSP input Analog input scaling Accuracy Input sampling period Setting method Indication method
Bank switching
Other functions Ambient operating temperature Ambient operating humidity Storage temperature
5
E5AN-H/E5EN-H
Input Ranges
Thermocouple/Platinum Resistance Thermometer (Fully Universal Inputs)
Input type Name
2300 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 -100.0 -200.0
-200.0-199.9 100.0 0.0 -50.00 -199.9 -200.0 200.00 100.0 100.0 0.0 -20.0 -50.00-100.0 -20.0 -50.00 -200.0-199.9 -50.00 -200.0 -100.0 -200.0-199.9-200.0 0.0 0.0 0.0 0.0 200.00 500.0 500.0 500.0 400.0 200.00 400.0 400.0 200.00 400.0 400.0 600.0 850.0 850.0 850.0 1300.0 1300.0 1300.0 1700.01700.0
Platinum resistance thermometer Pt100 JPt100 K J T
Thermocouple E L U N R S B
1800.0
Analog input W
2300.0
PL II
4 to 20 m A
0 to 20 m A
1 to 5V
0 to 5V
0 to 10 V
Temperature range (C)
Usable in the following ranges by scaling: -19999 to 32400, -1999.9 to 3240.0, -199.99 to 324.00, or -19.999 to 32.400
Setting number
0
1
2
24
3
4
5
6
21
7
8
22
9
10
23
11
12
13
14
15
16
17
18
19
20
25
26
27
28
29
Shaded settings are the default settings. The applicable standards for the input types are as follows: K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 584-1 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 W: W5Re/W26Re, ASTM E988-1990
JPt100: JIS C 1604-1989, JIS C 1606-1989 Pt100: JIS C 1604-1997, IEC 751 PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard)
6
E5AN-H/E5EN-H
Alarm Outputs
Each alarm can be independently set to one of the following 13 alarm types. The default is 2: Upper limit. Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified. Note: For models with heater burnout, SSR failure, and heater overcurrent detection, alarm 1 will be an OR output of the alarm selected from the following alarm types and the alarms for heater burnout, SSR failure, and heater overcurrent. To output only a heater burnout alarm, SSR failure alarm, and heater overcurrent alarm for alarm 1, set the alarm type to 0 (i.e., no alarm function). Alarm output operation Set value 0 1 2 3 4 Alarm type Alarm function OFF Upper- and lower-limit *1 Upper-limit Lower-limit Upper- and lower-limit range *1 Upper- and lower-limit with standby sequence *1 Upper-limit with standby sequence Lower-limit with standby sequence Absolute-value upper-limit Absolute-value lower-limit Absolute-value upper-limit with standby sequence Absolute-value lower-limit with standby sequence LBA (alarm 1 type only) PV change rate alarm RSP absolute value upper limit *6
ON OFF X 0
When alarm value When alarm value X is positive X is negative Output OFF
ON OFF ON OFF ON OFF L SP X SP X SP L SP L SP H H H
Description of function No alarm
*2
ON OFF ON OFF X SP X SP
Set the deviation in the set point by setting the alarm upper limit (H) and alarm lower limit (L). Set the upward deviation in the set point by setting the alarm value (X). Set the downward deviation in the set point by setting the alarm value (X). Set the deviation in the set point by setting the alarm upper limit (H) and alarm lower limit (L). A standby sequence is added to the upper- and lower-limit alarm (1). *7
X SP X SP X 0 X 0 X 0 X 0
ON OFF
*3 *4
5
ON OFF
*5
ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF
X SP X SP X 0 X 0 X 0 X 0
6 7 8 9 10 11 12 13 14
ON OFF ON OFF
A standby sequence is added to the upper-limit alarm (2). *7 A standby sequence is added to the lower-limit alarm (3). *7 The alarm will turn ON if the process value is larger than the alarm value (X) regardless of the set point. The alarm will turn ON if the process value is smaller than the alarm value (X) regardless of the set point. A standby sequence is added to the absolute-value upper-limit alarm (8). *7 A standby sequence is added to the absolute-value lower-limit alarm (9). *7 *8 *9 The alarm turns ON when the remote SP (RSP) is larger than the alarm value (X). This alarm functions in both Local SP and Remote SP Modes. The alarm turns ON when the remote SP (RSP) is smaller than the alarm value (X). This alarm functions in both Local SP and Remote SP Modes.
ON OFF ON OFF ON OFF
ON OFF
----ON OFF X 0
15
RSP absolute value lower limit *6
ON OFF
X 0
ON OFF
X 0
*1. With set values 1, 4 and 5, the upper and lower limit values can be set independently for each alarm type, and are expressed as "L" and "H." *2. Set value: 1, Upper- and lower-limit alarm
Case 1 Case 2 Case 3 (Always ON)
H < 0, L < 0 L H SP SP L H H > 0, L < 0 H > L H H SP L SP SP H L L H < 0, L > 0 H L H > 0, L < 0 H L H < 0, L > 0 H < L
*3. Set value: 4, Upper- and lower-limit range
Case 1 Case 2 Case 3 (Always ON)
*5. Set value: 5, Upper- and lower-limit with standby sequence Always OFF when the upper-limit and lower-limit hysteresis overlaps. *6. Displayed when there is a remote SP input. *7. Refer to the E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156) for information on the operation of the standby sequence. *8. Refer to the E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156) for information on the loop burnout alarm (LBA). *9. Refer to the E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156) for information on the PV change rate alarm.
H < 0, L < 0 L H SP SP L H H > 0, L < 0 H > L H H SP L SP SP H L L H < 0, L > 0 H L H > 0, L < 0 H L H < 0, L > 0 H < L
*4. Set value: 5, Upper- and lower-limit with standby sequence For Upper- and Lower-Limit Alarm Described Above * Case 1 and 2 Always OFF when the upper-limit and lower-limit hysteresis overlaps. * Case 3: Always OFF
7
E5AN-H/E5EN-H
Characteristics
Indication accuracy Thermocouple: (0.1% of indicated value or 1C, whichever is greater) 1 digit max. *1 Platinum resistance thermometer: (0.1% of indicated value or 0.5C, whichever is greater) 1 digit max. Analog input: 0.1% FS 1 digit max. CT input: 5% FS 1 digit max. Potentiometer input: 5% FS 1 digit max. Thermocouple input (R, S, B, W, PL II): (1% of PV or 10C, whichever is greater) 1 digit max. Other thermocouple input: (1% of PV or 4C, whichever is greater) 1 digit max. *3 Platinum resistance thermometer: (1% of PV or 2C, whichever is greater) 1 digit max. Analog input: (1%FS) 1 digit max. 60 ms Temperature input: 0.1 to 3240.0C or F (in units of 0.1C or F) Analog input: 0.01% to 99.99% FS (in units of 0.01% FS) Temperature input: 0.1 to 3240.0C or F (in units of 0.1C or F) Analog input: 0.1% to 999.9% FS (in units of 0.1% FS) 0.0 to 3240.0 s (in units of 0.1 s) 0.0 to 3240.0 s (in units of 0.1 s) 0.5, 1 to 99 s (in units of 1 s) 0.0 to 100.0% (in units of 0.1%) -19999 to 32400 (decimal point position depends on input type) Thermocouple: 0.1C/ max. (100 max.) Platinum resistance thermometer: 0.1C/ max. (10 max.) 20 M min. (at 500 VDC) 2,300 VAC, 50 or 60 Hz for 1 min (between terminals with different charge)
Transfer output accuracy 0.3% FS max. Influence of temperature *2 Influence of voltage *2 Input sampling period Hysteresis Proportional band (P) Integral time (I) Derivative time (D) Control period Manual reset value Alarm setting range Affect of signal source resistance Insulation resistance Dielectric strength Vibration resistance Shock resistance Weight
Malfunction 10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions Destruction 10 to 55 Hz, 0.75-mm single amplitude for 2 hrs each in X, Y, and Z directions Malfunction 100 m/s2, 3 times each in X, Y, and Z directions Destruction 300 m/s2, 3 times each in X, Y, and Z directions E5AN-H E5EN-H Controller: Approx. 310 g, Mounting Bracket: Approx. 100 g Controller: Approx. 260 g, Mounting Bracket: Approx. 100 g Front panel: IP66, Rear case: IP20, Terminals: IP00 Non-volatile memory (number of writes: 1,000,000 times) CX-Thermo version 4.0 or higher Provided on the bottom of the E5AN-H and E5EN-H. An E58-CIFQ1 USB-Serial Conversion Cable is required to connect the computer to the E5AN-H and E5EN-H. Provided on the front of the E5AN-H and E5EN-H. An E58-CIFIR USB-infrared Conversion Cable is required to connect the computer to the E5AN-H or E5EN-H. *4 UL 61010-1, CSA C22.2 No. 1010-1 EN 61010-1 (IEC 61010-1): Pollution level 2, overcurrent category II, Lloyd's standards *5
Degree of protection Memory protection Setup Tool Setup Tool port Approved standards Conformed standards
Standards
EMI: EN 61326 Radiated Interference Electromagnetic Field Strength: EN 55011 Group 1, class A Noise Terminal Voltage: EN 55011 Group 1, class A EMS: EN 61326 ESD Immunity: EN 61000-4-2 EMC Electromagnetic Field Immunity: EN 61000-4-3 Burst Noise Immunity: EN 61000-4-4 Conducted Disturbance Immunity: EN 61000-4-6 Surge Immunity: EN 61000-4-5 Power Frequency Magnetic Field Immunity: EN 61000-4-8 Voltage Dip/Interrupting Immunity: EN 61000-4-11 *1. The indication accuracy of K thermocouples in the -200 to 1300C range, T and N thermocouples at a temperature of -100C max., and U and L thermocouples at any temperatures is 2C 1 digit max. The indication accuracy of the B thermocouple at a temperature of 400C max. is not specified. The indication accuracy of B thermocouples in the 400 to 800C range is 3C max. The indication accuracy of the R and S thermocouples at a temperature of 200C max. is 3C 1 digit max. The indication accuracy of W thermocouples is 0.3% of PV or 3C, whichever is greater, 1 digit max. The indication accuracy of PL II thermocouples is 0.3% of PV or 2C, whichever is greater, 1 digit max. *2. Ambient temperature: -10C to 23C to 55C, Voltage range: -15% to 10% of rated voltage *3. K thermocouple at -100C max.: 10C max. *4. External communications (RS-232C, RS-485, or RS-422) and cable communications for the Setup Tool can be used at the same time. *5. Refer to information on maritime standards in Safety Precautions for E5@N/E5@N-H for compliance with Lloyd's Standards.
8
E5AN-H/E5EN-H
USB-Serial Conversion Cable
Applicable OS Applicable software Applicable models USB interface standard DTE speed Connector specifications Power supply Power supply voltage Current consumption Ambient operating temperature Windows 2000, XP, or Vista CX-Thermo version 4 or higher E5AN/E5EN/E5CN/E5CN-U/ E5AN-H/E5EN-H/E5CN-H/E5GN Conforms to USB Specification 1.1. 38400 bps Computer: USB (type A plug) Temperature Controller: Setup Tool port (on bottom of Controller) Bus power (Supplied from USB host controller.) 5 VDC 70 mA 0 to 55C (with no condensation or icing) -20 to 60C (with no condensation or icing) 10% to 80% 2,000 m max.
Current Transformer (Order Separately) Ratings
Dielectric strength Vibration resistance Weight Accessories (E54-CT3 only) 1,000 VAC for 1 min 50 Hz, 98 m/s2 E54-CT1: Approx. 11.5 g, E54-CT3: Approx. 50 g Armatures (2) Plugs (2)
USB-Infrared Conversion Cable
Applicable OS Applicable software Applicable models USB interface standard DTE speed Connector specifications Power supply Power supply voltage Current consumption Ambient operating temperature Windows 2000, XP, or Vista CX-Thermo version 4.0 or higher E5AN-H/E5EN-H Conforms to USB Specification 1.1. 38400 bps Computer: USB (type A plug) Temperature Controller: Infrared port (on front of Controller) Bus power (Supplied from USB host controller.) 5 VDC 80 mA 0 to 55C (with no condensation or icing) -20 to 60C (with no condensation or icing) 10% to 80% 2,000 m max.
Ambient operating humidity 10% to 80% Storage temperature Storage humidity Altitude
Weight Approx. 100 g Note: A driver must be installed in the personal computer. Refer to installation information in the operation manual for the Conversion Cable.
Communications Specifications
Transmission line RS-485, RS-422: Multipoint connection method RS-232C: Point-to-point Communications Synchronization method Protocol Baud rate Transmission code Data bit length * Stop bit length * Error detection Flow control Interface Retry function Communications buffer RS-485 (two-wire, half duplex) RS-422 (four-wire, half duplex) or RS-232C Start-stop synchronization CompoWay/F, SYSWAY, or Modbus 1200, 2400, 4800, 9600, 19200, 38400, or 57600 bps ASCII (CompoWay/F, SYSWAY) RTU (Modbus) 7 or 8 bits 1 or 2 bits Vertical parity (none, even, odd) Frame check sequence (FCS) with SYSWAY Block check character (BCC) with CompoWay/F or CRC-16 Modbus None RS-485, RS-422, or RS-232C None 217 bytes
Ambient operating humidity 10% to 80% Storage temperature Storage humidity Altitude Weight
Approx. 130 g (with mounting adaptor) Note: A driver must be installed in the personal computer. Refer to installation information in the operation manual for the Conversion Cable.
Heater Burnout Alarms, SSR Failure Alarms, and Heater Overcurrent Alarms
CT input (for heater current detection) Maximum heater current Input current indication accuracy Heater burnout alarm setting range *1 SSR failure alarm setting range *2 Models with detection for single-phase heaters: One input Models with detection for single-phase or three-phase heaters: Two inputs 50 A AC 5% FS 1 digit max. 0.1 to 49.9 A (in units of 0.1 A) Minimum detection ON time: 100 ms 0.1 to 49.9 A (in units of 0.1 A) Minimum detection OFF time: 100 ms
Communications 0 to 99 ms response wait time Default: 20 ms * The baud rate, data bit length, stop bit length, and vertical parity can be individually set using the Communications Setting Level.
Heater overcurrent alarm 0.1 to 49.9 A (in units of 0.1 A) setting range *3 Minimum detection ON time: 100 ms *1. For heater burnout alarms, the heater current will be measured when the control output is ON, and the output assigned to the alarm 1 function will turn ON if the heater current is lower than the set value (i.e., heater burnout detection current value). *2. For SSR failure alarms, the heater current will be measured when the control output is OFF, and the output assigned to the alarm 1 function will turn ON if the heater current is higher than the set value (i.e., SSR failure detection current value). *3. For heater overcurrent alarms, the heater current will be measured when the control output is ON, and the output assigned to the alarm 1 function will turn ON if the heater current is higher than the set value (i.e., heater overcurrent detection current value).
9
E5AN-H/E5EN-H
Electrical Life Expectancy Curve for Relays (Reference Values)
Life ( x 104 operations) 500 300 E5AN-H/E5EN-H 250 VAC, 30 VDC (resistive load) cos = 1
SSR Outputs (OUT1/OUT2) Ratings
* Rated load voltage: 75 to 250 VAC * Rated load current: 1 A (resistive load) Note: 1. The load current must be within the derating curve. 2. There is no zero-cross function.
100 50 30
Derating Curve for SSR Outputs (Reference Values)
Load current I (A) OUT1/OUT2 1.5
1.25 Condition B 1
10 5 3
0.75
1 0 1 2 3 4 5 6 Switching current (A)
0.5 Condition A 0.25
0 -10
0
10
20
30
40 45 50 55 60
Ambient temperature (C)
Condition A: SSR outputs 100% ON Condition B: SSR outputs 50% ON with 2-s control cycle
10
E5AN-H/E5EN-H
External Connections
Control output 1 and control output 2 are functionally isolated from the internal circuits.
Controllers
The Temperature Controller is set for a K-type thermocouple (input type = 5) by default. An input error (s.err) will occur if the input type setting does not agree with the temperature sensor. Check the input type.
Option Units
Communications E53-EN01 RS-232C
11 12 13 21
E53-EN02 RS-422
11 12 13 21 22
E53-EN03 RS-485
11 12 13 21 22
E53-AKB
11 12 13 21 22
Event Inputs EV2 EV1
SD RD SG DO NOT USE DO NOT USE
RDB RDA SG SDB SDA
B (+) A (-) DO NOT USE B (+) A (-)
* 100 to 240 VAC * 24 VAC/VDC (no polarity)
22
1 Input power supply 2 3 Control output 1 4 5 Control output 2 6 7 Auxiliary output 2 8 9 Auxiliary output 1 10
21 22 23 24 25 26 27 28 29 30
11 12 13
Event Inputs EV2 EV1 Potentiometer CT2 O W C 14 Auxiliary output 3 15 Auxiliary output 3 16 DO NOT USE mA DO NOT USE Relay output SPDT, 250 VAC, 3 A (resistive load) A heater burnout alarm, SSR failure, heater overcurrent alarm, input alarm, or Remote SP Input Error is sent to the output to which the alarm 1 function is assigned.
14 CT1 15 CT2 16 17 18 19 20
DO NOT DO NOT USE USE A DO NOT DO NOT V USE USE B B DO NOT USE
Control Output Unit Control outputs 1, 2 Control Output Unit Control outputs 1, 2 Refer to page 4 SSR Outputs 75 to 250 VAC, 1 A (resistive load) Models with Positionproportional Control Relay output 250 VAC, 1 A (including inrush current)
Auxiliary outputs 1, 2, 3
SSR Outputs
Models with Positionproportional Control
Event input/ Transfer output/ Remote SP 21 22 EV3 EV4 23 24 25
DO NOT USE
1 Input power supply 2 +
Output unit
1 Input power supply 2 3 SSR
1 Input power supply 2 3 Open 4 5 Closed 6 7
Auxiliary output 2
3 4 5 SSR 6 7
Auxiliary output 2
- +
Output unit
4 5 6 7 8 9
Auxiliary output 1 Auxiliary output 1
-
Auxiliary output 2
26 27 4 to 20 mA DC (Load: 600 max.) 28 29
4 to 20 mA DC
+
Transfer output
8 9
Auxiliary output 1
8 9 10
Relay output SPST-NO, 250 VAC, 3 A (resistive load)
- +
Remote SP input
10
10
-
30
Note: Wire all voltage input terminals correctly. The Controller may fail if voltage input terminals are wired incorrectly.
11
E5AN-H/E5EN-H
Nomenclature
E5AN-H
Temperature unit
E5EN-H
Operation indicators
SUB1 SUB2
SUB1 SUB2
PV
No.1 display Temperature unit
HA SUB3
Operation indicators
SUB3 HA
PV
No.1 display
SV
OUT1 RSP STOP OUT2 CMW MANU
No.2 display
RSP OUT1 STOP OUT2 CMW MANU
SV
No.2 display No.3 display
MV
No.3 display
Operation indicators
MV
Programmable Function Key/ Auto/Manual Key
Mode Key
Up Key Programmable Function Key/ Auto/Manual Key
PF
A/M
Up Key Level Key
Ir Ir
PF
A/M
E5AN-H
Down Key
E5EN-H
Level Key
Mode Key
Down Key
Dimensions
E5AN-H
Mounted Separately
92
+0.8 0
(Unit: mm)
Group Mounted *
(96 x number of units - 3.5)
+1.0 0
92
+0.8 0
120 min. 6 2
+0.8 0
Group mounting does not allow waterproofing.
79.2
92
96 x 96
112
91
* Recommended panel thickness is 1 to 8 mm. * Group mounting is not possible in the vertical direction. (Maintain the specified mounting space between Controllers.) * To mount the Controller so that it is waterproof, insert the waterproof packing onto the Controller. * When two or more Controllers are mounted, make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications.
* Group mounting is not possible if an SSR output is used for control output 1 or 2 and the E53-C3N or E53-C3DN Output Unit is used. For these combinations, maintain the following mounting space between Controllers.
Waterproof Packing (Accessory) Mounting Bracket (Accessory) Terminal Cover (E53-COV16) (Accessory) Crimp terminal size: M3.5 110 min. 92
+0.8 0
92
+0.8 0
120 min.
12
E5AN-H/E5EN-H
E5EN-H
Mounted Separately
+0.6 45 0
Group Mounted *
(48 x number of units - 2.5)
+1.0 0
92
+0.8 0
120 min.
Group mounting does not allow waterproofing.
+0.8 92 0
6 48 2
79.2
* Recommended panel thickness is 1 to 8 mm. * Group mounting is not possible in the vertical direction. (Maintain the specified mounting space between Controllers.) * When two or more Controllers are mounted, make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications.
* Group mounting is not possible if an SSR output is used for control output 1 or 2 and the E53-C3N or E53-C3DN Output Unit is used. For these combinations, maintain the following mounting space between Controllers.
96 112 91 45
+0.6 0
60 min.
92 Waterproof Packing (Accessory) Mounting Bracket (Accessory) Terminal Cover (E53-COV16) (Accessory) Crimp terminal size: M3.5 120 min.
+0.8 0
13
E5AN-H/E5EN-H
Accessories (Order Separately)
USB-Infrared Conversion Cable
E58-CIFIR
USB-Infrared Conversion Cable
(2,000) 54
35.8 USB connector (type A plug) 4.6 dia. LED indicator: RD LED indicator: SD
17.8
With Mounting Adapter Connected
Mounting Adapter
39
16 18.5
Mounting Adapter (Accessory)
99.2
21.8 (75)
23.1
USB-Serial Conversion Cable
E58-CIFQ1
(2,100) 250 LED indicator: SD 1,765
USB connector (type A plug)
LED indicator: RD
Serial connector
Terminal Covers
E53-COV16 (Six Covers provided.)
1.2 3.2
10
44.8
14
E5AN-H/E5EN-H
Waterproof Packing
Y92S-P4 (for DIN 96 x 96) Y92S-P5 (for DIN 48 x 96)
Order the Waterproof Packing separately if it becomes lost or damaged. The Waterproof Packing can be used to achieve an IP66 degree of protection. (Deterioration, shrinking, or hardening of the waterproof packing may occur depending on the operating environment. Therefore, periodic replacement is recommended to ensure the level of waterproofing specified in IP66. The time for periodic replacement depends on the operating environment. Be sure to confirm this point at your site. Consider one year a rough standard. OMRON shall not be liable for the level of water resistance if the customer does not perform periodic replacement.) The Waterproof Packing does not need to be attached if a waterproof structure is not required.
Current Transformers
E54-CT1
21 15 5.8 dia. 7.5 2.8
E54-CT1 Thru-current (Io) vs. Output Voltage (Eo) (Reference Values)
Maximum continuous heater current: 50 A (50/60 Hz) Number of windings: 4002 Winding resistance: 182
Output voltage (Eo) V (r.m.s.) 100 V 10 50 Hz
25
3 10.5 40 Two, 3.5 dia.
1 k Distortion factor 10% 3% 1%
1
10 30
100 mV 100 RL = 10
10
E54-CT3
2.36 dia. 30 12 dia. 9
1 100 V 10 1
10
100 mA
1
10
100 1,000 A
40 x 40
Thru-current (Io) A (r.m.s.)
Two, M3 (depth 4)
E54-CT3 Thru-current (Io) vs. Output Voltage (Eo) (Reference Values)
Maximum continuous heater current: 120 A (50/60 Hz) (Maximum continuous heater current for an OMRON Temperature Controller is 50 A.) Number of windings: 4002 Winding resistance: 80.8
Output voltage (Eo) V (r.m.s.) 100 V 10 50 Hz 1 k 500
15
30
E54-CT3 Accessory
* Armature
Approx. 3 dia.
Connection Example
Armature Plug Lead
1
Distortion factor 10% 3% 1%
100 mV 100 50 RL = 10 1 100 V 10 1
18
10
* Plug
Approx. 6 dia.
(22)
10
100 mA
1
10
100 1,000 A
Thru-current (Io) A (r.m.s.)
15
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions.
2009.11 In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company
http://www.ia.omron.com/
OMRON Corporation
(c)Copyright OMRON Corporation 2009 All Right Reserved.


▲Up To Search▲   

 
Price & Availability of E5AN-HAA2HBM-500

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X